TYMPSTAR PRO

COMPREHENSIVE TYMPANOMETER

The TympStar Pro™ performs a full battery of middle-ear measurements on patients of all ages. Audiologists will feel an instant comfort with the TympStar Pro’s consistent interface. GSI understands that efficiency is required in today’s busy audiology practice and strives to provide hearing healthcare professionals a versatile and reliable comprehensive middle-ear analyzer.

NEW TESTING OPTIONS

MULTI-FREQUENCY TEST

The addition of the Multi-Hz Test to the TympStar Pro provides audiologists the tools needed to confidently identify resonance frequency of the middle ear system. This powerful test can be completed five times faster than its predecessor and takes as little as 13 seconds to complete. Multi-Hz offers the efficiency and accuracy needed to assess pathologies in the middle ear system.

PATULOUS ET IDENTIFICATION

The TympStar Pro now has a dedicated test type to identify a patulous Eustachian tube. the capability to store measurements from four test conditions and an adjustable time base makes the Patulous ET Test a reliable, flexible, and customizable option to meet the need of every facility’s protocol.

QUICK, CONVENIENT TESTING

Use screening tympanogram and reflexes to quickly evaluate pediatric patients. The touch screen allows hearing health-care professionals to easily change test ears and test parameters, leaving more time to interact with patients.

CONFIDENCE IN TESTING

The TympStar Pro is a comprehensive middle-ear analyzer which takes precision to the next level. Evaluate neural integrity, reflex pathways and Eustachian tube function with one touch. Have complete confidence during reflex threshold testing with artifact-free tracings. Eliminate the “null” point that cancels out the reflex with multiplex pulsed-tone stimulation for ipsilateral reflex recordings.

STREAMLINE OPERATIONS

Benefit from Auto Start in both hearing screening and diagnostic tympanometry. Save time and improve consistency in testing with user defined auto sequence testing – perform tympanometry, reflex threshold and reflex decay testing with a single button press. Define patient or user specific test protocols that will adjust settings for immediate testing.

EVERY PATIENT POPULATION

Take advantage of multiple probe tone frequencies. Test a diverse patient population, all with differing middle-ear pathologies with 226, 678 and 1000 Hz probe tones. Utilize the manual pump control to offset peak pressure to achieve faster pump speeds for uncomfortable children. Validate electrode placement for cochlear implant patients with ESRT. Start and stop tests and switch test ears from the probe box so you can interface with difficult to test patients.

SAVE TIME WITH AUTO START

As soon as a seal is obtained in the ear, the sweep begins without any need to press buttons to save time with challenging patients.

KEY TYMPANOMETER FEATURES

1. TOUCH SCREEN MONITOR

The 12 inch color display allows the examiner to change parameters with a single touch of the screen.

2. CUSTOMIZABLE USER TESTS

The predefined protocols save time and create consistency in testing. Define auto sequence tests that are consistent with billing codes.

3. ZOOM FUNCTION

For detailed analysis, use the zoom to analyze test results. Verify peak pressure and mark/verify reflex thresholds.

4. MULTIPLE PROBE TONE FREQUENCIES

Test a diverse patient population with 226, 678, and 1000 Hz probe tones. These standard probe tones allow efficient testing on all.

5. STAND-ALONE, PC ENABLED

EMR/EHR compatible with GSI Suite for reporting and counseling.

6. FIVE TEST TYPE BUTTONS

Fast transition between tests for accurate and efficient testing. Tests include Screening, Tymp, Reflex, ETF, and More Tests.

DIAGNOSTIC TYMPANOMETRY

The components of tympanometry, Y, G and B, are recorded and stored simultaneously for each tympanogram tracing. The audiologist may access all immittance components for additional diagnostic information when test results are questionable.

ACOUSTIC REFLEX DECAY

After establishing reflex thresholds, transition to acoustic reflex decay testing begins with one button press. The appropriate stimulus level for each test frequency will be set based on the stored reflex threshold.

EUSTACHIAN TUBE FUNCTION (ETF)

Intact or perforated, all will be shown on the tympanogram. Displayed is a table of the test data with Vea, peak and shift daPa. There is also an area where instructions of next steps will be visible for the tester for easy diagnostics.

SCREENING TYMPANOMETRY

Perform a fast evaluation of the acoustic mechanic properties of the ear in the screening mode. Automatic start on seal for both 226 and 1,000 Hz probe tones ensures a fast picture of the middle-ear. It is possible to run up to 4 screening reflexes using any combination of ipsilateralor contralateral stimulation.

TYMPANOMETRIC EMR MADE EASY

GSI Suite is an audiologic data management software solution. With a single button press, data is transferred from the instrument to the software where it is stored and a report may be generated.